QC Command Center

The QC Command Center is the central dashboard for laboratory quality control in Vorian Connect. It combines real-time Westgard rule violation monitoring via SSE, exclusion auditing with one-click PDF reports, delta check review, Levey-Jennings charting, patient-value QC trending, and a multi-analyte QC heatmap — so QC specialists can monitor, investigate, and document every QC event from a single screen.

How It Works

What's Included

Where It Fits

The QC Command Center is the operational QC surface for lab managers and QC specialists. It consumes data from the continuous stats engine (which computes rolling precision statistics and detects Westgard violations), the auto-verification pipeline (which feeds delta check results), and the patient-value QC subsystem (which tracks moving patient distributions). The Command Center does not modify QC data — it displays, filters, and provides exclusion workflows that write audit-trailed exclusion records. It sits alongside the Observability dashboard (which shows message throughput and system health) and the Delta Checks page (which shows detailed per-patient delta comparisons). All QC data is tenant-isolated through PostgreSQL RLS — each lab sees only its own instruments, analytes, and violations.

Technical Details (for evaluators)

CapabilityDetail
Real-time updatesServer-Sent Events (SSE) — violations appear within seconds of detection, no polling
Westgard rulesDetected by continuous stats engine — standard multi-rule evaluation with per-analyte thresholds
Exclusion workflowConfigurable reason codes, per-exclusion audit trail with user + timestamp, CRUD API
Delta checksAbsolute and percentage thresholds — configurable per analyte, sourced from auto-verification pipeline
LJ chartingConfigurable analyte + date range, mean/SD lines, data from QC chart API endpoint
Patient-value QCMoving medians/means, PHI-safe (aggregate only, no MRNs/accessions/specimen IDs)
HeatmapAnalyte × instrument grid with in-control/warning/out-of-control status colors
Report exportPDF generation via exclusion report API with complete audit trail
API surfaceGET /api/qc/chart, GET /api/qc/exclusion-reasons, GET/POST/DELETE /api/qc/exclusions, GET /api/qc/exclusions/report, GET /api/qc/exclusions/report/pdf
Tenant isolationPostgreSQL RLS on all QC tables — instruments, analytes, violations, exclusions scoped to tenant

The QC Command Center is designed for clinical lab regulatory requirements. All exclusions are fully auditable with user attribution and timestamps. Exclusion reports are exportable as PDF for CLIA/CAP inspection readiness. Patient-value QC trending is PHI-safe — sample message IDs are included for traceability but MRNs, accession numbers, and specimen IDs are never exposed in aggregate QC views.